Overview
Regulatory and insurance frameworks often require periodic performance testing of deluge fire suppression systems.
Wet testing — discharging water through the system — causes corrosion, scale build-up, equipment damage, production disruption, and costly post-test cleaning and reinstatement. Yet the testing obligation remains non-negotiable.
Why It Happens
Wet testing requires bagging of electrical equipment, evacuation of operational areas, disposal of contaminated water, and post-test drying and inspection of all wetted systems. Corrosion under insulation (CUI) risk is elevated each time water saturates lagging. In some offshore or remote locations, water discharge is environmentally constrained or physically impractical, making wet testing logistically challenging.
How It Can Be Fixed
Replace wet testing with Paradigm’s Dry-Flo® dry testing technology. Dry-Flo® flows low-pressure conditioned air through the deluge system while sensors and software record flow performance, verify compliance with design specifications, and identify blockages or faults — all without discharging a single litre of water. DNV has qualified Dry-Flo® as an acceptable substitute for wet testing for up to 10 years.
Why Paradigm
This is where Paradigm makes the difference. With a field-proven global track record, we bring both the technology and the expertise to resolve stuck pig incidents quickly and safely. Our proprietary tools, including Find-Block® for pinpoint location and Pipe-Pulse® for controlled remediation, have been deployed successfully across some of the world’s most challenging pipelines. Safety is at the heart of our operations, ensuring that interventions minimize risk while restoring flow. More than just a service provider, Paradigm partners with operators to deliver long-term assurance—designing pigging strategies and preventive measures to keep pipelines running smoothly.
Explore the technology
Related services
Performance Test and Verification is Paradigm’s service for proving the integrity and real-world capability of deluge and firewater systems using evidence, not assumptions. We combine remote visual inspection with engineering verification to identify what’s happening inside your firewater
Foam Testing: Fire‑fighting foam testing is the process of evaluating foam concentrates and system performance to ensure they will work effectively during an emergency. It typically involves collecting representative foam samples, followed by laboratory analysis to check properties such as pH, specific
System Cleaning keeps deluge and firewater networks ready to perform when needed, without surprises at the worst possible moment. It’s a practical, cost-effective way to restore flow capacity, remove hidden restrictions, and keep your fire protection system compliant.
Inspections of fire suppression systems involve a systematic check to ensure all components would function properly when called upon. This process typically includes external and internal inspections where suitable. Inspections can vary depending on equipment. Some may require just a visual
Pipe fabrication is the process of cutting, preparing, assembling and the fitting of pipework that forms the fire suppression system of an asset. Fabrication involves cutting pipes to precise lengths, threading or grooving ends, attaching the required fittings so that each section matches the
Maintenance of fire suppression systems involves routine inspections, testing and servicing to ensure the equipment operates effectively in an emergency. It typically includes checking components such as controls, extinguishing agents (gaseous), piping networks, discharge mechanisms for damage